THE EFFECT OF AIR CONDITIONERS (AC) ON PULMONARY FUNCTIONS IN YOUNG ADULTS

Maturi Lavanya *1, Rajanand Gaikwad 2.

*1 Associate prof. department of physiology Santhiram medical college, Nandyal; Kurnool, Andhrapradesh, India.

2 Professor and Head of the department of physiology Santhiram medical college, Nandyal; Kurnool, Andhrapradesh, India.

Corresponding Author: Dr. Maturi Lavanya, Associate Professor, Department of physiology Santhiram medical college, Nandyal, Kurnool, Andhrapradesh, India. Phone: +919573726030 E-Mail: janvita.lr@gmail.com

Abstract:

Modern styles of living in urban areas have been considered to be potentially responsible for the development of airway problems and for the reduction in the pulmonary functional capacities. One of the components of the modern life style is the intensive use of air conditioners, which has caused the increased inhalation of cold dry air ultimately leading to an alteration in the pulmonary functions. The inhalation of cold dry air for long periods makes the airway smooth muscle more sensitive. Abrupt changes in the air temperature may induce rhinitis even in the absence of the usual triggering allergy. The existence of bronchospasm in response to nasal inhalation of cold and/or dry air may be considered as a protective mechanism that tends to reduce the airflow rate in the upper airways and cervical trachea and limits the penetration of insufficiently conditioned inspired air into the lungs. Cold dry air challenge test is the test by which bronchial responsiveness is measured by applying physical stimuli like hyperventilation of cold and dry air. It has been observed that hyperventilation of cold dry air causes bronchoconstriction, and eupnoeic inhalation of cold, dry air increases airway resistance in asthmatic patients in AC environment, the current study was carried out on young adults using air condition and non-air condition, 66 subjects between the age group of 25-50 years chosen for the study, the subjects was then divided into two groups viz, group A & group B. The subjects of both the groups then examined for their FVC, FEV1 and PEFR values FVC and FEV1 ratio was also documented for each subjects. The best of the three readings was recorded and finally the data was analyzed using standard deviation and‘t’ test. There was a difference in the data after the analysis of standard deviation and ‘t’ test hence it was found that FVC, FEV1 and FEV1/FVC is higher in Non-air conditioner users compare to air conditioner users. But there is no significant difference between the PEFR level between Air conditioner and non-air conditioner users. Hence it can be concluded that non air conditioner users have higher pulmonary function when compared to air conditioner users.

KEYWORDS: ac users, PFT, PEFR, FEF25–75% and FEV1.

REFERENCES

  1. Khaliq F, Sharma S, Tandon OP. Pumonary functions in air conditioner users. Indian J Physiol Pharmacol 2006;50(1):67-72.
  2. Malo JL, Cartier A, E Archeveque J, Ghezzo H, Martin RR. Cold air inhalation has a cumulative bronchospastic effect when inhaled in consecutive doses for progressively increasing degrees of ventilation. Am Rev Respir Dis 1986;134:990-3.
  3. Hahn A, Anderson SD, Morton AR, Black JL, Fitch KD. A reinterpretation of the effect of temperature and water content of the inspired air in exercise-induced asthma. Am Rev Respir Dis 1984; 130:575-9.
  4. Van Strien RT, Gehring U, Belanger K, Triche E, Gent J, Bracken MB, et.al. The influence of air conditioning, humidity, temperature and other household characteristics on mite allergen concentrations in the northeastern United States. Allergy 2004;59(6): 645–52.
  5. Wickman MT, Nordwall SL, Pershagen G, Sundell J, Schwarts B. House dust mite sensitization in children and residential characteristics in a temperate region. J Allergy Clin Immunol 1993;88:89–95.
  6. Takaoka M. House dust mites in the Japanese indoor environment. Allergology 1997; 4:367–73.
  7. De Filippis P, Spinaci A, Cola M, Maggi O, Pana A. Effectiveness of the maintenance operations on the air conditioning systems of a university building in relation to the microbiological quality of the air indoor. Ig Sanita Pubbl 2003;59(6): 365–72.
  8. Kuwahara Y, Kondoh J, Tatara K, Azuma E, Nakajima T, Hashimoto M, Komachi Y. Involvement of urban living environments in atopy and enhanced eosinophil activity: potential risk factors of airway allergic symptoms. Allergy 2001;56: 224–30.
  9. Hosein HR, Corey P, Robertson J Mc D. The effect of domestic factors on respiratory symptoms andFEV1. Int J Epidemiology 1989; 18(2): 390–6.
  10. Dhaar GM, Rabbani I. Environmental Pollution. In: Dhaar GM, Rabbani I, editors. Foundation of Community Medicine. 2 nd ed. Noida, UP: Elsevier; 2008. p. 91.
  11. Rundell KW, Jenkinson DM. Exercise induced bronchospasm in the elite athlete. Sports Med 2002;32:583-600.
  12. Kippelen P, Caillaud C, Robert E, Connes P, et al. Effect of endurance training on lung function: A one year study. Br J Sports Med 2005;39:617-21.
  13. Baur X, Richter G, Pethran A, Czuppon AB, Schwaiblmair M. Increased prevalence of IgG induced sensitization and hypersensitivity pneumonitis (humidifier lung) in non smokers exposed to aerosols of a contaminated air conditioner. Respiration 1992; 59(4): 211–4.
  14. William JB, Stremski E, Eljaiek L, Aufderheide TP. Freon inhalational abuse presenting with ventricular fibrillation. Am J Emerg Med 1994;12: 533–6.
  15. Banaszak EF, Theide Wh, Fink JN. Hpersensitivity penumonitis due to contamination of an air conditioner. N Engl J Med 1970;283:271-6.
  16. Kumar P, Marier R, Leechs H. Respiratory allergies related to automobile air conditioners. N Engl J Med 1984;311:1619-21.
  17. Kumar P, Marier R, Leech SH. Hypersensitivity penumonitis due to contamination of a car air conditioner. N Engl J Med 1981;305:1531-2.
  18. Kumar P, Lopez M, Fan W, Cambre K, Elston RC. Mold contamination of automobile air conditioner systems. Ann Allergy 1990; 64(2):174-7.
  19. Pierre Fontanari, Henri Burnet, Marie CarolinZattara-Hartmann, Yves Jammes. Changes in airway resistance induced by nasal inhalation of cold dry, dry, or moist air in normal individuals.J ApplPhysiol. 1996:81:1739-43.
  20. Togias AG, Naclerio RM. Nasal challenge with cold, dry air results in release of inflammatory mediators. Possible mast cell involvement.J Clin Invest. 1985;76(4):1375-81.
  21. Cruz AA, Togias A. Upper airways reactions to cold air.Curr Allergy Asthma Rep. 2008;8(2):111-7.
  22. Benson M.K. Bronchial hyper reactivity. British Journal of Diseases of Chest.1987; 27; 254-63.
  23. Babitha, R. Rangarajan, M. Muhil, M.G. Basavarajaiah. Pulmonary Function Tests in Air Conditioner Users.Journal of Clinical and Diagnostic Research 2011;5(3): 532-5.
  24. De Filippis P, Spinaci A, Coia M, Maggi O, Pana A. Effectiveness of the maintenance operations on the air conditioning systems of a university building in relation to the microbiological quality of the air indoor. IgSanitaPubbl. 2003; 59(6): 365-72
  25. Kuwahara, J. Kondoh, K. Tatara, E. Azuma, T. Nakajima, M. Hashimoto. Involvement of urban living environments in atopy and enhanced eosinophil activity: potential risk factors of airway allergic symptoms. Allergy 2001; 56: 224- 30.
  26. Baur X, Richter G, Pethran A, Czuppon A.B, Schwaiblmair M. Increased prevalence of IgG-induced sensitization and hypersensitivity pneumonitis (humidifier lung) in nonsmokers exposed to aerosols of a contaminated air conditioner. Respiration 1992; 59(4): 211-4.
  27. Hoffman RE, Wood RC, Kreiss K. Building-related asthma in Denver office workers. Am J Public Health 1993;83:89-93.

 

Download Full Text TOC